Date Opened: 05/20/2019

Site Address:
Nellson Nutraceutical Llc
5115 E. La Palma Ave
Anaheim, CA 92807

Mailing Address:
5115 E. La Palma Ave, Anaheim, CA 92807

Union Status: NonUnion

SIC:

NAICS: 424490/Other Grocery and Related Products Merchant Wholesalers


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/07/2019

Emphasis:

Case Closed: 01/13/2020


Related Activity
Type Activity Nr Safety Health
Accident 1455415 Yes Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $18,000 $0 $0 $750 $0 $18,750
Current Penalty $18,000 $0 $0 $475 $0 $18,475
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3314(G) 10/08/2019 10/31/2019 $475 $750 $0 11/06/2019 O - Administrative Law Judge Order  
2. 02001 Serious 3314(D) 10/08/2019 10/31/2019 $18,000 $18,000 $0 11/06/2019 O - Administrative Law Judge Order  

Investigation Summary

Investigation Nr: 119517.015
Event: 05/09/2019
Employee amputates thumb after hitting button when distracte

At 1:45 p.m. on May 9, 2019, an employee was in the process of setting up a Berthel Line 17A horizontal packaging machine which is equipped with an interlocked door and an optional maintenance mode during which the interlock is rendered inactive. The employee was setting up the aluminum film while the machine was in the maintenance mode. The employee was jogging the machine with his left hand on the control panel button while using his right hand to pull scrap foil out of the machine. In the jog mode, moving parts in the machine normally stop as soon the hand is off the jog button. The employee reported that he took his left hand off the jog button before placing his right hand in the machine but his left hand accidentally slipped back onto the jog button when he was distracted by a coworker. The employee amputated half of his right thumb on the cutting knife when the machine cycled, requiring medical treatment. The employee was not hospitalized.

Keywords: Amputated, Amputation, Caught In, Door, Finger, Hand, Hand Control, Inattention, Interlock, Knife, Lost Control, Machine Cycled, Machine Guarding, Machine operator, Partial Amputation, Point Of Operation, Set Up, Sheared, Thumb

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1402304.015 26 M Non Hospitalized injury Millwrights
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.