Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1398943.015 - T & C Stainless

Inspection Information - Office: Kansas City Area Office

 

Inspection Nr: 1398943.015
Report ID: 0728500
Date Opened: 05/06/2019

Site Address:
T & C Stainless
1016 Progress St
Mount Vernon, MO 65712

Mailing Address:
1016 Progress St, Mount Vernon, MO 65712

Union Status: NonUnion

SIC:

NAICS: 332439/Other Metal Container Manufacturing


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/06/2019

Emphasis: L:Repvehicle

Case Closed: 08/09/2021


Related Activity
Type Activity Nr Safety Health
Referral 1449920 Yes
Inspection 1416162 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $18,564 $0 $0 $0 $0 $18,564
Current Penalty $0 $0 $0 $11,138 $0 $11,138
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 19100107 C08 08/21/2019 09/17/2019 $5,569 $9,282 $0 I - Informal Settlement  
2. 01002A Other 19100107 D02 08/21/2019 09/17/2019 $5,569 $9,282 $0 I - Informal Settlement  
3. 01002B Other 19100107 D12 08/21/2019 09/17/2019 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 116027.015
Event: 04/27/2019
Welder is burned when fumes inside tank ignite

At 6:30 a.m. on April 27, 2019, an employee was working for a firm that manufactured metal containers. He was working as a welder. He was doing some patchwork on a tank that had penetrant and developer chemicals within. He was welding from the outside of the tank. As he stuck his hand into the tank to begin welding, the fumes were ignited. The employee suffered burns to his right hand, arms, and shoulder. He was hospitalized. The fumes had accumulated inside the tank due to inadequate ventilation. It was also noted that a portable electric light was in use inside a tank while workers were spraying chemicals within the tank.

Keywords: Arm, Burn, Electric Light--Port, Flammable Vapors, Hand, Shoulder, Spray Booth, Spray Painting, Tank, Ventilation, Welder, Welding

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1398943.015 36 M Hospitalized injury Welders and cutters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.