Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1398771.015 - Littoral Marine, Llc.

Inspection Information - Office: Tampa Area Office

 

Inspection Nr: 1398771.015
Report ID: 0420600
Date Opened: 05/07/2019

Site Address:
Littoral Marine, Llc.
1520 Industrial Drive
Wildwood, FL 34785

Mailing Address:
1520 Industrial Drive, Wildwood, FL 34785

Union Status: NonUnion

SIC:

NAICS: 336612/Boat Building


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/12/2019

Emphasis:

Case Closed: 08/25/2020


Related Activity
Type Activity Nr Safety Health
Referral 1451755 Yes
Inspection 1404161 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 4 4
Initial Penalty $21,216 $0 $0 $0 $0 $21,216
Current Penalty $10,608 $0 $0 $0 $0 $10,608
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100106 D04 I 09/09/2019 02/25/2020 $2,652 $5,304 $0 I - Informal Settlement  
2. 01002 Serious 19100106 E02 IV C 09/09/2019 $2,652 $5,304 $0 I - Informal Settlement  
3. 01003 Serious 19100106 H08 III 09/09/2019 10/25/2019 $2,652 $5,304 $0 I - Informal Settlement  
4. 01004 Serious 19100157 G01 09/09/2019 $2,652 $5,304 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 116017.015
Event: 04/19/2019
Employee sustains third degree burns to hand and leg

At 9:10 a.m. on April 19, 2019, an employee was working for a firm that built boats. He was installing a wiring harness on the aft section of a boat. As he did this, he was lying on a mover's blanket. He had used acetone to clean the dirty areas of the boat and his hands. The bottle of acetone was leaking, and the vapors from the previously used acetone were lingering on the mover's blanket and on the employee. When the employee lit a torch to heat shrink the wires on the harness, the open flames ignited the nearby flammable vapors. The employee suffered third-degree burns to his right leg and arm. He was hospitalized.

Keywords: Acetone, Boat, Burn, Cleaning, Electric Cable, Electrical Work, Electrician, Fire Extinguisher, Flammable Vapors, Hand, Installing, Leak, Leg, Open Flame, Training

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1398771.015 54 M Hospitalized injury Laborers, except construction
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.