Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1397731.015 - Armorock, Llc

Inspection Information - Office: Nv-E-Las Vegas 0953220

 

Inspection Nr: 1397731.015
Report ID: 0953220
Date Opened: 05/01/2019

Site Address:
Armorock, Llc
14555 Us Highway 95 South
Boulder City, NV 89005

Mailing Address:
(Hand Delivery Mandatory) Po Box 6006, Boulder City, NV 89006

Union Status: NonUnion

SIC:

NAICS: 327390/Other Concrete Product Manufacturing


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/25/2019

Emphasis: N:Amputate

Case Closed: 07/05/2019


Related Activity
Type Activity Nr Safety Health
Referral 1451395 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $3,150 $0 $0 $0 $0 $3,150
Current Penalty $3,150 $0 $0 $0 $0 $3,150
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100179 L03 I 06/28/2019 $3,150 $3,150 $0 Z - Issued  

Investigation Summary

Investigation Nr: 115935.015
Event: 05/01/2019
Employee amputates thumb while assembling and welding mold

At approximately 12:00 a.m. on May 1, 2019, an employee was assembling and welding a steel mold for a cement product. The employee was placing an approximately 4 foot in diameter, 3/4 inch thick steel plate on the top of the mold. The employee was using a magnet with a welded eyelet hung from a Jet overhead gantry crane to move the steel plate on top of the mold. When the employee was lowering the plate, the plate became separated from the magnet and fell. The employee had his left hand placed around the rim of the mold, with his thumb on top of the inside edge. When the steel plate fell, his thumb became pinched between the plate and the mold, severing the thumb. The employee's left thumb was amputated. The employee was hospitalized for these injuries.

Keywords: Amputated, Carbon Steel Plate, Gantry Crane, Magnet, Mold, Pinched, Thumb, Welding

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1397731.015 61 M Hospitalized injury Solderers and brazers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close