Inspection Detail
Inspection: 1396227.015 - Sta-Bilt Construction Company
Inspection Information - Office: Iowa 0751910
Site Address:
Sta-Bilt Construction Company
1339 Nishna Avenue
Harlan, IA 51537
Mailing Address:
P.O. Box 151, Harlan, IA 51537
Union Status: NonUnion
SIC:
NAICS: 237310/ Highway, Street, and Bridge Construction
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/26/2019
Emphasis:
Case Closed: 06/04/2019
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1448315 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 4 | 4 | ||||
| Current Violations | 4 | 4 | ||||
| Initial Penalty | $5,540 | $0 | $0 | $0 | $0 | $5,540 |
| Current Penalty | $5,540 | $0 | $0 | $0 | $0 | $5,540 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 19100219 D01 | 05/20/2019 | 06/14/2019 | $1,385 | $1,385 | $0 | Z - Issued | ||
| 2. | 01001B | Serious | 19100219 E01 I | 05/20/2019 | 06/14/2019 | $0 | $0 | $0 | Z - Issued | ||
| 3. | 01002 | Serious | 19100303 F02 | 05/20/2019 | 06/14/2019 | $1,385 | $1,385 | $0 | Z - Issued | ||
| 4. | 01003 | Serious | 19100333 A01 | 05/20/2019 | 06/14/2019 | $1,385 | $1,385 | $0 | Z - Issued | ||
| 5. | 01004 | Serious | 19100333 C02 | 05/20/2019 | 06/14/2019 | $1,385 | $1,385 | $0 | Z - Issued |
Investigation Summary
At 7:45 a.m. on April 23, 2019, Employee #1, employed by a highway construction company, was using an Extech 430 Multi Meter to perform a diagnostic test on a 480 volt 50 amp circuit ITE circuit breaker that was not functioning in an emulsion tank electrical panel. When the employee touched the positive and negative test leads of the meter to the power supply side of the circuit breaker, an arc flash occurred. The arc flash burned the test leads of the meter and the tops of multiple fingers on the employee's hands. The employee, who had not been wearing personal protective equipment, was transported to the hospital, where he was admitted for treatment of the burns.
Keywords: Circuit Breaker, Construction, Electric Arc, Electric Meter, Electrical Testing, Electrical panel, Finger, Hand, PPE, Tank, Work Rules
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1396227.015 | 44 | M | Hospitalized injury | Not specified mechanics and repairers |