Inspection Detail
Inspection: 1395901.015 - University Of Utah Health Care Clinic
Inspection Information - Office: Utah Division Of Occupational Safety And Health
Site Address:
University Of Utah Health Care Clinic
1950 Circle Of Hope
Salt Lake City, UT 84113
Mailing Address:
125 S Fort Douglas Blvd, Salt Lake City, UT 84113
Union Status: NonUnion
SIC:
NAICS: 622110/General Medical and Surgical Hospitals
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/25/2019
Emphasis:
Case Closed: 06/07/2019
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 1449159 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100028 B03 I | 05/16/2019 | 06/10/2019 | $0 | $0 | $0 | Z - Issued |
Investigation Summary
At 8:00 a.m. on April 25, 2019, an employee was working for a general medical and surgical hospital. He was the director/manager of facilities and engineering. His employer had sent him to find a water leak. He was working in a parking garage. He was troubleshooting a leaking fire riser. Without wearing fall protection, he entered an axillary drain room. This room was also part of a ventilation system for carbon monoxide control for the parking garage. In the room, there was a large unguarded hole that went between two levels of the parking garage. The room was dark, with no artificial light source. There was minimal natural light that was blocked by several wood planks above the hole. A coworker reported that at the time of the incident, the room was dark. The employee fell through the hole and landed on a concrete floor. He fell 3.4 meters (11 feet). He received five broken ribs, a broken scapula, and an injury to his spleen. He was hospitalized.
Keywords: Carbon Monoxide, Collarbone, Fall, Fall Protection, Fire Ext System, Floor Hole, Floor Opening, Fracture, Guardrail, Leak, Maintenance, Poor Visibility, Rib, Spleen, Unguarded Fl Opening, Ventilation, Walking Surface
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1395901.015 | 59 | M | Hospitalized injury | Engineering technicians, n.e.c. |