Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1394464.015 - Archrock Services, Lp

Inspection Information - Office: Bismarck Area Office

 

Inspection Nr: 1394464.015
Report ID: 0830300
Date Opened: 04/11/2019

Site Address:
Archrock Services, Lp
Mid-South Compressor Station 12286 36th Street Nw
Watford City, ND 58854

Mailing Address:
Attn: Taleia Wilson 9807 Katy Freeway, Suite 100, Houston, TX 77024

Union Status: NonUnion

SIC:

NAICS: 213112/Support Activities for Oil and Gas Operations


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/11/2019

Emphasis: L:Oilgas

Case Closed: 12/10/2019


Related Activity
Type Activity Nr Safety Health
Referral 1447275 Yes
Inspection 1394497 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $13,260 $0 $0 $0 $0 $13,260
Current Penalty $0 $0 $0 $13,260 $0 $13,260
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Other 19100106 H07 I A 09/25/2019 10/01/2019 $13,260 $13,260 $0 I - Informal Settlement  
2. 01001B Serious 19100307 C 09/25/2019 10/01/2019 $0 $0 $0 I - Informal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 115521.015
Event: 04/08/2019
Employee is burned in flash fire at compressor station

At 9:00 a.m. on April 8, 2019, an employee was troubleshooting an electronics system that controlled a valve for a natural gas compressor system. The employee used a Dewalt DCF 883 power drill to disassemble a check valve to determine if the valve was experiencing mechanical failure and had removed the second bolt when the condensate ignited. The employee had been wearing FRC clothing, eye protection, and gloves; however, he was hospitalized with several burns to his hands and face.

Keywords: Burn, Compressed Gas, Compressor, Face, Gas Leak, Hand, PPE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1394464.015 30 M Hospitalized injury Installers And Repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close