Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1394409.015 - Stellar Field Service, Inc.

Inspection Information - Office: Bismarck Area Office

 

Inspection Nr: 1394409.015
Report ID: 0830300
Date Opened: 02/15/2019

Site Address:
Stellar Field Service, Inc.
5307 151st Avenue Nw
Williston, ND 58801

Mailing Address:
5074 Jackie Avenue, Williston, ND 58801

Union Status: NonUnion

SIC:

NAICS: 213112/Support Activities for Oil and Gas Operations


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/15/2019

Emphasis: L:Oilgas

Case Closed: 09/17/2019


Related Activity
Type Activity Nr Safety Health
Referral 1426554 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $9,282 $0 $0 $0 $0 $9,282
Current Penalty $5,569 $0 $0 $0 $0 $5,569
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100110 C05 I J 08/05/2019 08/09/2019 $5,569 $9,282 $0 I - Informal Settlement  
2. 01001B Serious 19101200 H02 II 08/05/2019 08/09/2019 $0 $0 $0 I - Informal Settlement  
3. 01001C Serious 19101200 H03 I 08/05/2019 08/09/2019 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 115513.015
Event: 02/13/2019
Two employees are injured when vacuum trailer explodes

At 11:30 a.m. on February 13, 2019, Employee # 1 was using a propane torch (weed burner) to thaw a discharge valve on a vacuum trailer that had been frozen closed. The trailer had previously been used to haul production water (brine water). Employee #2 was working nearby. After applying the open flame to the valve for approximately 30 seconds the tank exploded. The explosion was presumably the result of over pressurization of the cargo tank as a result of the ignition of hydrocarbon vapors or gases that had remained in the tank after the last load of production water had been emptied at a disposal site. Employee # 1 sustained burns, bone fractures, and was struck by shrapnel. He was hospitalized at a burn treatment center. Employee # 2 was struck by shrapnel. He was hospitalized.

Keywords: Burn, Chemical Vapor, Explosion, Flammable Vapors, Fracture, Frozen, Gas, High Pressure, Open Flame, Propane, Propane Torch, Shrapnel, Trailer, Valve, Vapor, Water

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1394409.015 50 M Hospitalized injury Truck drivers, heavy
2 1394409.015 35 M Hospitalized injury Truck drivers, heavy
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close