Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1392670.015 - Coastal Great Southern

Inspection Information - Office: Columbia Area Office

 

Inspection Nr: 1392670.015
Report ID: 0418500
Date Opened: 04/09/2019

Site Address:
Coastal Great Southern
Southeast End Of Wando Welch Terminal
Mount Pleasant, SC 29464

Mailing Address:
321 Grange Road, Savannah, GA 31407

Union Status: Union

SIC:

NAICS: 488390/Other Support Activities for Water Transportation


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/11/2019

Emphasis:

Case Closed: 07/24/2019


Related Activity
Type Activity Nr Safety Health
Referral 1445161 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 1 2 3
Initial Penalty $26,520 $0 $0 $0 $0 $26,520
Current Penalty $7,956 $0 $0 $7,956 $0 $15,912
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 19100178 L01 II 06/21/2019 $3,410 $5,684 $0 I - Informal Settlement  
2. 01002 Other 19170011 A 06/21/2019 $4,546 $7,576 $0 I - Informal Settlement  
3. 01003A Serious 19170152 D01 VI 06/21/2019 $0 $13,260 $0 I - Informal Settlement Citation has been deleted.
4. 01003B Serious 19170152 D01 XVI 06/21/2019 $7,956 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 116694.015
Event: 04/08/2019
Employee incurs multiple injuries when truck explodes

At 4:00 a.m. on April 8, 2019, an employee was driving a GMC Savana van converted into a utility truck returning to the laydown yard after working a ship. The driver took a left turn and approached the terminal when the truck exploded and erupted into a ball of flame. The entire back of the truck was removed and the cab and truck frame containing the driver rolled a few feet forward and stopped rolling after striking a Jersey barrier. A fire had started near an arc-welder on the truck and when it reached gas welding hoses on the floor an acetylene hose was burned through. The acetylene and oxygen tanks were not turned off at the tank or the regulator and gas was released into the back of the truck reaching its LEL when the explosion occurred. The employee sustained multiple injuries and was hospitalized.

Keywords: Acetylene, Chemical, Chemical Reaction, Cylinder, Explosion, Fire, Flammable Vapors, Gas, Gas Leak, Gas Powered Welder, Mechanic, Oxygen, Repair, Shipyard, Truck, Welder

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1392670.015 40 M Hospitalized injury Mechanical controls and valve repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close