Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1387516.015 - Ascend Performance Materials Inc.

Inspection Information - Office: Birmingham Area Office

 

Inspection Nr: 1387516.015
Report ID: 0418300
Date Opened: 03/21/2019

Site Address:
Ascend Performance Materials Inc.
1050 Chemstrand Avenue
Decatur, AL 35601

Mailing Address:
1050 Chemstrand Avenue, Decatur, AL 35601

Union Status: NonUnion

SIC:

NAICS: 325199/All Other Basic Organic Chemical Manufacturing


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/22/2019

Emphasis:

Case Closed: 09/18/2019


Related Activity
Type Activity Nr Safety Health
Referral 1435621 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 2 3
Current Violations 1 2 3
Initial Penalty $8,695 $0 $0 $0 $0 $8,695
Current Penalty $6,087 $0 $0 $0 $0 $6,087
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 08/16/2019 $6,087 $8,695 $0 I - Informal Settlement  
2. 02001 Other 19100025 B03 08/16/2019 09/12/2019 $0 $0 $0 I - Informal Settlement  
3. 02002 Other 19100028 B11 II 08/16/2019 09/12/2019 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 114735.015
Event: 03/13/2019
Employee is sprayed with HMD when valve is left open

At 8:00 a.m. on March 13, 2019, an employee was working for a manufacturer of basic organic chemicals. He was opening a valve to permit the flow of hexamethylenediamine (HMD). The valve had been actuated to rinse and purge feed lines. It had been left open by the previous shift. The employee forgot to check valve positions before opening the HMD flow valve. He was sprayed with HMD, and he suffered second-degree burns to his groin. He was hospitalized.

Keywords: Abdomen, Burn, Caustic, Chemical Burn, Hip, Leg, Open Valve, Pelvis, Penis, Shut-Off Valve, Sprayed, Thigh, Valve

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1387516.015 72 M Hospitalized injury Laborers, except construction
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close