Inspection: 1387362.015 - Mississippi Lime Company
Inspection Information - Office: Jackson Area Office
Site Address:
Mississippi Lime Company
1543 Haining Rd
Vicksburg, MS 39183
Mailing Address:
1543 Haining Rd, Vicksburg, MS 39183
Union Status: NonUnion
SIC:
NAICS: 811118/Other Automotive Mechanical and Electrical Repair and Maintenance
Inspection Type: Fat/Cat
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/29/2019
Emphasis:
Case Closed: 09/05/2019
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 1440194 | ||
Referral | 1433116 | Yes | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | 2 | |||
Current Violations | 1 | 1 | 2 | |||
Initial Penalty | $13,260 | $0 | $0 | $0 | $0 | $13,260 |
Current Penalty | $13,260 | $0 | $0 | $0 | $0 | $13,260 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 5A0001 | 09/03/2019 | $13,260 | $13,260 | $0 | Z - Issued | |||
2. | 02001 | Other | 19100253 B04 | 09/03/2019 | 09/18/2019 | $0 | $0 | $0 | Z - Issued |
Investigation Summary
At 7:45 p.m. on March 22, 2019, an employee died from third-degree burns he suffered when an oily rag ignited after coming into contact with a propane heater. The employee was hospitalized, where he remained for sixteen days before his death.
Keywords: Burn, Fire, Flammable Liquid, Heater, Propane
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1387362.015 | 64 | M | Fatality | Helpers, mechanics and repairers |