Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1385552.015 - Pro-Air, Inc.

Inspection Information - Office: Baltimore Area Office

 

Inspection Nr: 1385552.015
Report ID: 0316100
Date Opened: 03/15/2019

Site Address:
Pro-Air, Inc.
1319 F Street Nw
Washington, DC 20004

Mailing Address:
7081 Dorsey Run Road Suite 2h, Elkridge, MD 21075

Union Status: Union

SIC:

NAICS: 238220/ Plumbing, Heating, and Air-Conditioning Contractors


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/03/2019

Emphasis:

Case Closed: 06/03/2019


Related Activity
Type Activity Nr Safety Health
Referral 1433732 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $0 $0 $0 $6,521 $0 $6,521
Current Penalty $0 $0 $0 $4,565 $0 $4,565
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 19040039 A02 05/03/2019 $4,565 $6,521 $0 I - Informal Settlement  
2. 01002 Other 19040041 A02 05/03/2019 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 114528.015
Event: 02/16/2019
Employee testing water main sustains leg fracture

At 10:00 a.m. on February 16, 2019, Employee #1, employed by a plumbing contractor, was testing a water main moving water into a commercial building as part of the building's rehabilitation. He was tightening bolts on an end cap when the cap blew off and struck his lower leg. Emergency services transported the employee to the hospital, where he was admitted and treated for a fractured leg.

Keywords: Bolt, Connector, Construction, Frac Tank, High Pressure, Leg, Plumbing, Rehabilitation, Struck By, Test Equipment, Water Pipe

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1385552.015 37 M Hospitalized injury Plumber, pipefitter and steamfiter apprentices
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close