Inspection Detail
Inspection: 1383846.015 - Pinnacle Campus Living, Llc
Inspection Information - Office: Tampa Area Office
Site Address:
Pinnacle Campus Living, Llc
Haven 46
Tampa, FL 33613
Mailing Address:
5055 Keller Springs Road Ste 400, Addison, TX 75001
Union Status: NonUnion
SIC:
NAICS: 721310/Rooming and Boarding Houses
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 03/06/2019
Emphasis:
Case Closed: 10/18/2022
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 1432367 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | 2 | |||
Current Violations | ||||||
Initial Penalty | $9,472 | $0 | $0 | $9,472 | $0 | $18,944 |
Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19101000 A01 | 06/17/2019 | $0 | $9,472 | $0 | 07/15/2019 | F - Formal Settlement | Citation has been deleted. | |
2. | 02001 | Other | 19040039 A02 | 06/17/2019 | $0 | $9,472 | $0 | 07/15/2019 | F - Formal Settlement | Citation has been deleted. |
Investigation Summary
At 2:08 p.m. on March 2, 2019, an employee was operating a gas powered pressure washer that released carbon monoxide fumes. The employee inhaled these fumes and suffered carbon monoxide poisoning. The employee was hospitalized.
Keywords: Carbon Monoxide, Gas, Inhalation, Poisoning
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1383846.015 | 24 | M | Hospitalized injury |