Inspection Detail
Inspection: 1380513.015 - Seimens Gamesa Renewable Energy
Inspection Information - Office: Wichita Area Office
Site Address:
Seimens Gamesa Renewable Energy
1000 Commerce Str.
Hutchinson, KS 67501
Mailing Address:
1000 Commerce Str., Hutchinson, KS 67501
Union Status: NonUnion
SIC:
NAICS: 333611/Turbine and Turbine Generator Set Units Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 02/22/2019
Emphasis: N:Amputate, L:Repvehicle
Case Closed: 02/26/2019
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 1427743 | Yes |
Investigation Summary
At 9:07 a.m. on February 15, 2019, an employee was attaching a sling to a crane when a board fell, striking the employee in his right arm. The employee fractured his arm and was hospitalized.
Keywords: Arm, Board, Crane, Falling Object, Fracture, Struck By
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1380513.015 | 60 | M | Hospitalized injury | Laborers, except construction |