Inspection Detail
Inspection: 1379728.015 - Northeastern Products Corporation
Inspection Information - Office: Miosha General Industry Safety & Health Division
Site Address:
Northeastern Products Corporation
85 N Brady Ave
Caspian, MI 49915
Mailing Address:
85 N Brady Ave, Caspian, MI 49915
Union Status: NonUnion
SIC:
NAICS: 321219/Reconstituted Wood Product Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 02/26/2019
Emphasis: N:Amputate, S:Fall, S:Injury/Illness
Case Closed: 04/26/2019
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1426152 | Yes |
Investigation Summary
At 9:00 a.m. on February 11, 2019, an employee was unplugging a jammed auger and amputated the tip of his right hand's index finger when it was caught between a pulley and belt. The employee was hospitalized.
Keywords: Amputated, Amputation, Auger, Belt, Caught By, Finger, Fingertip, Jammed, Pulley
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1379728.015 | 30 | M | Hospitalized injury | Machine operators, not specified |