Inspection Detail
Inspection: 1377675.015 - Service Wire Company Manufacturing
Inspection Information - Office: Charleston Area Office
Site Address:
Service Wire Company Manufacturing
310 Davis Road
Culloden, WV 25510
Mailing Address:
310 Davis Road, Culloden, WV 25510
Union Status: NonUnion
SIC:
NAICS: 335929/Other Communication and Energy Wire Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/03/2018
Emphasis: P:Amputate, N:Amputate
Case Closed: 11/21/2019
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1405171 | Yes |
Investigation Summary
At 8:30 a.m. on November 30, 2018, an employee was adjusting the rollers in a rewind machine and pinched a finger between the roller and wire. The employee amputated his finger and was hospitalized.
Keywords: Amputated, Amputation, Finger, Pinched, Roller--Mach/Part
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1377675.015 | 20 | M | Hospitalized injury | Laborers, except construction |