Inspection Detail
Inspection: 1377336.015 - Arcos Industries, Llc
Inspection Information - Office: Wilkes Barre Area Office
Site Address:
Arcos Industries, Llc
394 Arcos Drive
Mount Carmel, PA 17851
Mailing Address:
394 Arcos Drive, Mount Carmel, PA 17851
Union Status: Union
SIC:
NAICS: 333992/Welding and Soldering Equipment Manufacturing
Inspection Type: Referral
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 02/15/2019
Emphasis: N:Amputate
Case Closed: 02/19/2019
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1423951 | Yes |
Investigation Summary
At 6:00 p.m. on February 5, 2019, an employee was feeding wire into a wire drawing machine and caught two of his fingers from his left hand in a loop and amputated the fingertips. The employee was hospitalized.
Keywords: Amputated, Amputation, Caught By, Caught In, Finger, Fingertip, Hand
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1377336.015 | 24 | M | Non Hospitalized injury | Machine operators, not specified |