Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1369469.015 - Innovative Rotational Molding, Inc.

Inspection Information - Office: Fresno District Office

 

Inspection Nr: 1369469.015
Report ID: 0950625
Date Opened: 01/04/2019

Site Address:
Innovative Rotational Molding, Inc.
2300 W. Pecan Ave
Madera, CA 93637

Mailing Address:
2300 W. Pecan Ave, Madera, CA 93637

Union Status: NonUnion

SIC:

NAICS: 326199/All Other Plastics Product Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/30/2019

Emphasis:

Case Closed: 07/09/2019


Related Activity
Type Activity Nr Safety Health
Accident 1413062
Inspection 1369482 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $7,200 $0 $0 $0 $0 $7,200
Current Penalty $2,700 $0 $0 $0 $0 $2,700
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 3203(A)(7)(C) 02/08/2019 $2,700 $7,200 $0 02/11/2019 O - Administrative Law Judge Order  

Investigation Summary

Investigation Nr: 112948.015
Event: 12/27/2018
Employee is crushed by 300 pound lid

At 7:26 a.m. on December 27, 2018, Employee #1 was taking a mold apart. Employee #1 and a coworker were removing the molds off of a rotating piece of equipment, which holds four molds. In order to remove the mold, the perimeter and center bolts had to be removed. The mold had clamps around the perimeter of the mold, but those would be removed once the bolts had been taken off the unit. A hydraulic device was placed underneath the mold to hold the mold lid in place, once the clamps were released. As the perimeter clamps and bolts were released, Employee #1 started removing the center bolts and the 300 pound lid came off of the unit and landed on top of the employee. The employee suffered kidney, liver and lung injuries and was hospitalized.

Keywords: Crushed, Falling Object, Hydraulic Tool, Kidney, Liver, Lung, Mold, Rotating Parts, Struck By

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1369469.015 18 M Hospitalized injury Machine operators, not specified
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.