Investigation Summary

Investigation Nr: 115767.015
Event: 04/25/2018
Employee receives chemical burn on foot and lower leg from s

At 4:45 p.m. on April 25, 2018, a maintenance technician was trying to respond to and disconnect the high level flow sensor in the acid farm area. The maintenance technician stepped into the containment area which had sulfuric acid in it. It overflowed his work boot and he received 2nd degree chemical burns to foot and lower leg.

Keywords: Chemical Burn, Foot, Leg, Sulfuric Acid

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1365159.015 24 M Hospitalized injury
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.