Inspection Detail
Inspection: 1362583.015 - Ecr International, Inc.
Inspection Information - Office: Syracuse Area Office
Site Address:
Ecr International, Inc.
2201 Dwyer Avenue
Utica, NY 13501
Mailing Address:
2201 Dwyer Avenue, Utica, NY 13501
Union Status: NonUnion
SIC:
NAICS: 332410/Power Boiler and Heat Exchanger Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/28/2018
Emphasis: N:Amputate
Case Closed: 12/18/2018
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1400818 | Yes | |
| Inspection | 1363460 | Yes |
Investigation Summary
At 9:45 a.m. on November 14, 2018, an employee was setting a heat exchanger down on a base and pinched he tip of his left hand's index finger. The employee amputated the tip of his finger. Hospitalization was not required.
Keywords: Amputated, Amputation, Caught Between, Finger, Fingertip, Pinched
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1362583.015 | 31 | M | Hospitalized injury | Assemblers |