Inspection Detail
Inspection: 1360007 - Playmade Products
Inspection Information - Office: Houston North Area Office
Site Address:
Playmade Products
20001 Oil Center Blvd
Houston, TX 77090
Mailing Address:
8323 Bojack, Houston, TX 77040
Union Status: NonUnion
SIC:3599
NAICS: 0
Inspection Type: Accident
Scope: No Insp/Other
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/24/1984
Emphasis:
Case Closed: 08/28/1984
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360574925 |
Investigation Summary
The owner of a company that designed, built, and installed a Pentex overhead crane at a remote location arrived at that site to repair electrical problems in a pendant control for the crane. He requested that the control remain energized so that he could check the wiring. He walked down the rail on the south side of the shop to get to the bridge of the crane. He then went out on one of the bridge girders, reached out 600 to 900 millimeters, and opened the electrical box. There were no guardrails on the bridge girders or rails. In addition, the company owner was not using personal fall arrest equipment. While he was working on the box, he apparently contacted an energized part of the circuit. He froze to the circuit until the main circuit breaker for the crane tripped, and then he fell about 9.1 meters to the floor. He died of electrocution.
Keywords: E GI II, ELEC PROTECT EQUIP, ELECTRICAL, ELECTROCUTED, ELECTRICAL WORK, ELEC CIRC PART--MISC, FALL, FALL PROTECTION, ELECTRICAL BOX
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1360007 | Fatality | Electric Shock | Chief exec's & gen'l administrators, public admin. |