Inspection Detail
Inspection: 1359434.015 - Pti Royston, Llc
Inspection Information - Office: Atlanta East Area Office
Site Address:
Pti Royston, Llc
545 Old Elbert Rd
Royston, GA 30662
Mailing Address:
545 Old Elbert Rd, Royston, GA 30662
Union Status: NonUnion
SIC:
NAICS: 325412/Pharmaceutical Preparation Manufacturing
Inspection Type: Referral
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/08/2018
Emphasis: N:Amputate, L:Forklift
Case Closed: 03/26/2019
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 1396728 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 4 | 4 | ||||
Current Violations | 4 | 4 | ||||
Initial Penalty | $53,040 | $0 | $0 | $0 | $0 | $53,040 |
Current Penalty | $30,000 | $0 | $0 | $0 | $0 | $30,000 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100029 B02 | 02/26/2019 | $7,500 | $13,260 | $0 | I - Informal Settlement | |||
2. | 01002 | Serious | 19100147 C04 II | 02/26/2019 | 03/22/2019 | $7,500 | $13,260 | $0 | I - Informal Settlement | ||
3. | 01003 | Serious | 19100147 C06 I | 02/26/2019 | 03/22/2019 | $7,500 | $13,260 | $0 | I - Informal Settlement | ||
4. | 01004 | Serious | 19100147 C07 I | 02/26/2019 | 03/22/2019 | $7,500 | $13,260 | $0 | I - Informal Settlement |
Investigation Summary
At 12:45 p.m. on October 30, 2018, Employee #1 was cleaning the machine mold press. The employee's arm became caught in the mold press, amputating it.
Keywords: Amputated, Arm, Caught In, Molding Machine, Press
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1359434.015 | 33 | M | Hospitalized injury | Machine operators, not specified |