Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1358600.015 - Fleetwood Drywall, Inc.

Inspection Information - Office: Syracuse Area Office

 

Inspection Nr: 1358600.015
Report ID: 0215800
Date Opened: 11/02/2018

Site Address:
Fleetwood Drywall, Inc.
321-323 South Salina Street
Syracuse, NY 13202

Mailing Address:
3196 Cold Springs Road, Baldwinsville, NY 13027

Union Status: NonUnion

SIC:

NAICS: 238310/Drywall and Insulation Contractors


Inspection Type: Referral

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/02/2018

Emphasis: L:Fall, L:Gutreh

Case Closed: 08/14/2019


Related Activity
Type Activity Nr Safety Health
Referral 1398844 Yes
Inspection 1358616 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $3,031 $0 $0 $0 $0 $3,031
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19260501 B04 I 04/16/2019 $0 $3,031 $0 I - Informal Settlement Citation has been deleted.
2. 01001B Other 19260503 A01 04/16/2019 05/03/2019 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 110757.015
Event: 11/01/2018
Employee falls through floor hole and sustains multiple frac

At 12:45 p.m. on November 1, 2018, an employee was preparing to install a transition between a wall made of drywall panels and a metal ceiling. At some point, the employee fell thirteen feet through a two foot by four foot hole in the floor. The employee was hospitalized for multiple fractures to unspecified body parts.

Keywords: Fall, Fall Protection, Floor Hole, Floor Opening, Fracture, Installing

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1358600.015 40 M Hospitalized injury Drywall installers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.