Inspection Detail
Inspection: 1352133.015 - Guy F. Atkinson Construction, Llc
Inspection Information - Office: Baltimore Area Office
Site Address:
Guy F. Atkinson Construction, Llc
8751 Wisconsin Ave.
Bethesda, MD 20814
Mailing Address:
350 Indiana St. Suite 600, Golden, CO 80401
Union Status: Union
SIC:
NAICS: 237990/Other Heavy and Civil Engineering Construction
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/09/2018
Emphasis:
Case Closed: 03/12/2020
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 1389996 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $13,260 | $0 | $0 | $0 | $0 | $13,260 |
| Current Penalty | $0 | $0 | $0 | $26,520 | $0 | $26,520 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 19100147 C07 III C | 04/05/2019 | 05/01/2019 | $26,520 | $13,260 | $0 | 04/29/2019 | F - Formal Settlement |
Investigation Summary
At 1:15 p.m. on October 5, 2018, an employee was loosening pneumatic clamp fittings with an impact gun and a 70 inch long 4 inch diameter steel pipe that connected a large air compressor blew loose. The employee was struck by the pipe and suffered massive upper body trauma,, killing him.
Keywords: Compressor, Pipe, Steel, Struck By
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1352133.015 | 35 | M | Fatality | Operating engineers |
Translate