Inspection Detail
Inspection: 1348520.015 - Basf Catalysts Llc
Inspection Information - Office: Savannah Area Office
Site Address:
Basf Catalysts Llc
141 Englehard Road
Attapulgus, GA 39815
Mailing Address:
P.O. Box 220, Attapulgus, GA 39815
Union Status: NonUnion
SIC:
NAICS: 325188/All Other Basic Inorganic Chemical Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/24/2018
Emphasis:
Case Closed: 12/14/2018
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1384817 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $0 | $0 | $0 | $7,068 | $0 | $7,068 |
| Current Penalty | $0 | $0 | $0 | $4,241 | $0 | $4,241 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 19040039 A02 | 09/27/2018 | $4,241 | $7,068 | $0 | I - Informal Settlement |
Investigation Summary
At 8:45 a.m. on April 11, 2018, an employee was checking equipment. The u-drain was not secure and the employee stepped in hot condensate, resulting in burns to the feet.
Keywords: Burn, Hot Water
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1348520.015 | 51 | M | Hospitalized injury | Mechanical controls and valve repairers |
Translate