Inspection Detail
Inspection: 1346707.015 - Bureau Of Reclamation
Inspection Information - Office: Omaha Area Office
Site Address:
Bureau Of Reclamation
1706 W. 3rd St.
Mccook, NE 69001
Mailing Address:
1706 W. 3rd St., Mccook, NE 69001
Union Status: NonUnion
SIC:
NAICS: 924120/Administration of Conservation Programs
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership:
Safety/Health: Health
Close Conference: 09/17/2018
Emphasis: N:Fedtarg
Case Closed: 12/07/2018
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1382080 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 19040039 A02 | 11/06/2018 | 12/04/2018 | $0 | $0 | $0 | Z - Issued |
Investigation Summary
At 10:00 a.m. on August 7, 2018, an employee was repairing a window at a dam site and was using a shop vacuum to suck up some dirt when it malfunctioned, spewing dirt into his face. The employee was exposed to histoplasmosis and was hospitalized due to exposure to a biological or fungal agent. The employee was hospitalized.
Keywords: Repair, Vacuum Cleaner
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1346707.015 | 50 | M | Hospitalized injury |
Translate