Inspection Detail
Inspection: 1344099.015 - Nagel Precision Inc
Inspection Information - Office: Miosha General Industry Safety & Health Division
Site Address:
Nagel Precision Inc
288 Dino Dr
Ann Arbor, MI 48103
Mailing Address:
288 Dino Dr, Ann Arbor, MI 48103
Union Status: NonUnion
SIC:
NAICS: 333517
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/11/2018
Emphasis:
Case Closed: 01/29/2019
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 1381561 |
Investigation Summary
At 12:05 p.m. on September 5, 2018, an employee returned from lunch and had been relaxing near an intersection of a conveyor and a machine. The employee was found unresponsive and possibly electrocuted when he made contact with the conveyor and machine at the same time.
Keywords: Electrocuted, Unconsciousness
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1344099.015 | 49 | M | Fatality | Occupation Not Listed |