Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1344003.015 - Precast Wall Systems, Inc.

Inspection Information - Office: Fort Lauderdale Area Office

 

Inspection Nr: 1344003.015
Report ID: 0418800
Date Opened: 09/04/2018

Site Address:
Precast Wall Systems, Inc.
1199 W. Lantana Road
Lake Worth, FL 33462

Mailing Address:
1888 Nw 22nd Court, Pompano Beach, FL 33069

Union Status: NonUnion

SIC:

NAICS: 238120/Structural Steel and Precast Concrete Contractors


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/05/2018

Emphasis: L:Ohpwrlne

Case Closed: 04/15/2019


Related Activity
Type Activity Nr Safety Health
Referral 1378304 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 2 1 3
Initial Penalty $15,912 $0 $0 $0 $0 $15,912
Current Penalty $11,140 $0 $0 $0 $0 $11,140
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19261408 B01 03/04/2019 04/12/2019 $6,498 $9,282 $0 I - Informal Settlement  
2. 01001B Serious 19261410 D01 03/04/2019 04/12/2019 $0 $0 $0 I - Informal Settlement  
3. 01002A Serious 19261408 G01 I 03/04/2019 04/12/2019 $4,642 $6,630 $0 I - Informal Settlement  
4. 01002B Serious 19261430 B 03/04/2019 04/12/2019 $0 $0 $0 I - Informal Settlement  
5. 02001 Other 19261408 A01 03/04/2019 04/12/2019 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 113719.015
Event: 09/04/2018
Two employees are shocked when crane line contacts power lin

On September 4, 2018, Employees #1 and #2 and coworkers, employed by a precast concrete construction company, were using a crane to install concrete wall panels into previously installed concrete columns for a new building. The crane's load line made contact with energized overhead power lines while Employees #1 and #2 were guiding the wall panels by hand. The two employees sustained electric shocks of 7,620 volts to multiple areas of their bodies. Emergency services transported the employees to the hospital, where they were admitted for treatment.

Keywords: Burn, Concrete Panel, Construction, Contact, Crane, Electric Shock, Electric current, Energized, Installing, Load Line, Overhead Power Line

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1344003.015 39 M Hospitalized injury Construction Laborer
2 1344003.015 40 M Hospitalized injury Construction laborers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.