Inspection Detail
Inspection: 1343538.015 - Crown Technical Systems
Inspection Information - Office: San Bernardino District Office
Site Address:
Crown Technical Systems
13470 Philadelphia Avenue
Fontana, CA 92337
Mailing Address:
13470 Philadelphia Avenue, Fontana, CA 92337
Union Status: NonUnion
SIC:
NAICS: 334515/Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 01/16/2019
Emphasis:
Case Closed: 02/19/2019
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 1372434 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 3 | 3 | ||||
| Current Violations | 3 | 3 | ||||
| Initial Penalty | $0 | $0 | $0 | $1,495 | $0 | $1,495 |
| Current Penalty | $0 | $0 | $0 | $1,495 | $0 | $1,495 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3664(A) | 01/16/2019 | $375 | $375 | $0 | Z - Issued | |||
| 2. | 01002 | Other | 6151(E)(2) | 01/16/2019 | $560 | $560 | $0 | Z - Issued | |||
| 3. | 01003 | Other | 6151(C)(1) | 01/16/2019 | $560 | $560 | $0 | Z - Issued |
Investigation Summary
At 1:20 p.m. on August 15, 2018, an employee was rearranging the panels on a pallet and caught his right hand's pinky between two panels. The employee amputated his finger and was treated at Kaiser Permanente Hospital. Hospitalization was not required.
Keywords: Amputated, Amputation, Board, Caught Between, Finger, Pallet
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1343538.015 | 55 | M | Non Hospitalized injury | Helpers, mechanics and repairers |