Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1343383.015 - M&K Employee Solutions, Llc - Summit

Inspection Information - Office: Chicago South Area Office

 

Inspection Nr: 1343383.015
Report ID: 0521700
Date Opened: 08/31/2018

Site Address:
M&K Employee Solutions, Llc - Summit
7900 Bulldog Drive
Summit, IL 60501

Mailing Address:
7900 Bulldog Drive, Summit, IL 60501

Union Status: Union

SIC:

NAICS: 811118/Other Automotive Mechanical and Electrical Repair and Maintenance


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 10/15/2018

Emphasis: L:Piv

Case Closed: 11/15/2018


Related Activity
Type Activity Nr Safety Health
Referral 1374760 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $33,259 $0 $0 $0 $0 $33,259
Current Penalty $19,956 $0 $0 $0 $0 $19,956
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100132 D01 10/18/2018 11/14/2018 $7,761 $12,934 $0 I - Informal Settlement  
2. 01001B Serious 19100132 F01 10/18/2018 12/06/2018 $0 $0 $0 I - Informal Settlement  
3. 01002 Serious 19100178 L04 I 10/18/2018 11/14/2018 $5,543 $9,239 $0 I - Informal Settlement  
4. 01003A Serious 19101200 E01 10/18/2018 12/06/2018 $6,652 $11,086 $0 I - Informal Settlement  
5. 01003B Serious 19101200 G08 10/18/2018 12/06/2018 $0 $0 $0 I - Informal Settlement  
6. 01003C Serious 19101200 H03 III 10/18/2018 11/14/2018 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 108773.015
Event: 08/23/2018
Employee sustains burns to body when sprayed by heated solut

At 9:30 p.m. on August 23, 2018, an employee was working under a truck while flushing the coolant system and touched its hose, dislodging it unexpectedly and spraying the employee with a heated water solution. The employee sustained second degree burns to his face, chest, and arm. The employee was hospitalized.

Keywords: Arm, Automotive Repair, Burn, Chest, Face, Hot Water

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1343383.015 33 M Hospitalized injury Technicians, n.e.c.
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close