Powered by GoogleTranslate

Inspection Detail

Inspection: 1340587 - Fred Berglund & Sons Inc

Inspection Information - Office: Chicago South Area Office

 

Inspection Nr: 1340587
Report ID: 0521700
Date Opened: 08/10/1984

Site Address:
Fred Berglund & Sons Inc
2000 Lincoln Hwy
Sauk Village, IL 60411

Mailing Address:
8410 South Chicago Ave, Chgo, IL 60617

Union Status: Union

SIC:1542

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/23/1984

Emphasis:

Case Closed: 01/02/1985


Related Activity
Type Activity Nr Safety Health
Accident 360514319
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $600 $0 $0 $0 $0 $600
Current Penalty $600 $0 $0 $0 $0 $600
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19260021 B02 11/29/1984 12/02/1984 $360 $360 $0 -  
2. 01001B Serious 19260550 A15 I 11/29/1984 12/02/1984 $0 $0 $0 -  
3. 01002 Serious 19260550 A17 11/29/1984 12/02/1984 $240 $240 $0 -  

Investigation Summary

Investigation Nr: 570168
Event: 08/10/1984
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU CRANE

TWO EMPLOYEES WERE GUIDING A 23-FOOT-BY-6-FOOT GANG FORM INTO POSITION. DURING THIS OPERATION, THE HYDRAULIC TRUCK CRANE (P & H MODEL T-180) FROM WHICH THE FORMS WERE SUSPENDED CONTACTED A 7200-VOLT OVERHEAD POWER LINE. CURRENT PASSED THROUGH THE BOOM, THE LOAD LINE, THE WIRE ROPE SLINGS, THE STEEL-FRAMED FORMS, AND THE EMPLOYEES TO GROUND. THESE TWO WORKERS WERE ELECTROCUTED. TWO OTHER EMPLOYEES STANDING A FEW FEET FROM THE FIRST TWO ALSO RECEIVED ELECTRIC SHOCKS. THESE TWO EMPLOYEES WERE SHOCKED EITHER BECAUSE THEY WERE ALSO IN CONTACT WITH THE FORMS OR BECAUSE OF ELECTRIC POTENTIAL GRADIANTS IN THE GROUND.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, CRANE BOOM, POTENTIAL GRADIENT, ELECTROCUTED, E C, ELECTRIC SHOCK, CRANE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1340587 Hospitalized injury Electric Shock Occupation not reported
2 1340587 Hospitalized injury Electric Shock Occupation not reported
3 1340587 Fatality Electric Shock Occupation not reported
4 1340587 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close