Inspection Detail
Inspection: 1336326.015 - Dormakaba Usa Inc.
Inspection Information - Office: Birmingham Area Office
Site Address:
Dormakaba Usa Inc.
3440 Stanwood Boulevard
Huntsville, AL 35811
Mailing Address:
3440 Stanwood Boulevard, Huntsville, AL 35811
Union Status: NonUnion
SIC:
NAICS: 332321/Metal Window and Door Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 01/16/2019
Emphasis:
Case Closed: 01/02/2020
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1365841 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 3 | 4 | |||
| Current Violations | 1 | 3 | 4 | |||
| Initial Penalty | $11,366 | $0 | $0 | $9,472 | $0 | $20,838 |
| Current Penalty | $7,388 | $0 | $0 | $6,157 | $0 | $13,545 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 19101200 H03 II | 01/24/2019 | 02/20/2019 | $7,388 | $11,366 | $0 | I - Informal Settlement | ||
| 2. | 01001B | Serious | 19101200 H03 III | 01/24/2019 | 02/20/2019 | $0 | $0 | $0 | I - Informal Settlement | ||
| 3. | 02001 | Other | 19040039 A02 | 01/24/2019 | $6,157 | $9,472 | $0 | I - Informal Settlement | |||
| 4. | 02002 | Other | 19100132 D01 | 01/24/2019 | 02/20/2019 | $0 | $0 | $0 | I - Informal Settlement | ||
| 5. | 02003 | Other | 19100134 C02 I | 01/24/2019 | 02/20/2019 | $0 | $0 | $0 | I - Informal Settlement |
Investigation Summary
At 10:00 a.m. on July 24, 2018, three employees were operating the glue machine while the exhaust fan was not operating. Two employees suffered respiratory issues due to occupational asthma while the third employee had left the area to climb to the roof to get a serial number for the exhaust fan. Employees #1 and #2 were hospitalized due to their respiratory issues.
Keywords: Exhaust System, Fan, Respiratory
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1336326.015 | 40 | M | Hospitalized injury | Assemblers | |
| 2 | 1336326.015 | 59 | M | Hospitalized injury | Machinery maintenance occupations | |
| 3 | 1336326.015 | 51 | M | Hospitalized injury | Assemblers |