Inspection Detail
Inspection: 1334085 - G & M Corp
Inspection Information - Office: Cincinnati Area Office
Site Address:
G & M Corp
S Paint St
Chillicothe, OH 45601
Mailing Address:
25 N Clinton St, Dayton, OH 45402
Union Status: NonUnion
SIC:1796
NAICS: 0
Inspection Type: Unprog Rel
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/08/1984
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 06/27/1986
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360648497 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $400 | $0 | $0 | $0 | $0 | $400 |
Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 19260028 A | 11/15/1984 | 11/18/1984 | $0 | $400 | $0 | I - Informal Settlement |
Investigation Summary
A WORKER WAS ATTEMPTING TO DISLODGE AN OVERHEAD CRANE WITH A CROW BAR. HE WAS POSITIONED ABOVE FLOOR LEVEL AND WAS NOT PROVIDED WITH FALL PROTECTION. HE CONTACTED CIRCUIT PARTS ENERGIZED AT ABOUT 600 VOLTS AND RECEIVED AN ELECTRIC SHOCK. HE DIED, BUT IT WAS NOT REPORTED WHETHER HE FELL OR WAS ELECTROCUTED.
Keywords: ELECTRICAL, OVERHEAD CRANE, ELECTRIC SHOCK, ELEC CIRC PART--MISC, FALL PROTECTION, E C, CRANE, PRY BAR
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1334085 | Occupation Not Listed |