Inspection Detail
Inspection: 1333179.015 - Mastec Services Company, Inc.
Inspection Information - Office: Austin Area Office
Site Address:
Mastec Services Company, Inc.
3136 South East River Rd,
Martindale, TX 78655
Mailing Address:
2716 East 5th Street, Austin, TX 78702
Union Status: NonUnion
SIC:
NAICS: 237110/Water and Sewer Line and Related Structures Construction
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/26/2018
Emphasis: L:Constr6
Case Closed: 01/23/2020
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 1362968 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | ||||||
Initial Penalty | $12,934 | $0 | $0 | $0 | $0 | $12,934 |
Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19260960 C01 III B | 09/20/2018 | 09/27/2018 | $0 | $12,934 | $0 | 10/02/2018 | F - Formal Settlement | Citation has been deleted. |
Investigation Summary
At 9:45 a.m. on July 24, 2018, Employee #1, employed by a power transmission services company, was installing new overhead electrical lines. He made contact with an energized, 7,200-volt line and was shocked and burned. Emergency services transported the employee to the hospital, where he was admitted and treated for electric shock and third-degree burns.
Keywords: Burn, Construction, Contact, Elec Utility Work, Electric Shock, Electric current, Electrical, Electrician, Energized, Installing, Overhead Power Line, Power Line Worker, Power Lines, Shock
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1333179.015 | 30 | M | Hospitalized injury | Electrical power installers and repairers |