Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1332875.015 - Southwest Pump & Drilling, Inc

Inspection Information - Office: Long Beach District Office

 

Inspection Nr: 1332875.015
Report ID: 0950635
Date Opened: 07/25/2018

Site Address:
Southwest Pump & Drilling, Inc
3714 E Florence Ave.
Huntington Park, CA 90255

Mailing Address:
53381 Hwy 111, Coachella, CA 92236

Union Status: NonUnion

SIC:

NAICS: 237110/Water and Sewer Line and Related Structures Construction


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/18/2019

Emphasis:

Case Closed: 01/22/2020


Related Activity
Type Activity Nr Safety Health
Accident 1361806
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 1 1
Initial Penalty $0 $0 $0 $2,610 $0 $2,610
Current Penalty $0 $0 $0 $825 $0 $825
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 43000040 A 01/18/2019 02/25/2019 $0 $275 $0 02/05/2019 O - Administrative Law Judge Order Citation has been deleted.
2. 01002 Other 1509(A) 01/18/2019 02/25/2019 $825 $825 $0 02/05/2019 O - Administrative Law Judge Order  
3. 01003 Other 1613(B) 01/18/2019 02/25/2019 $0 $685 $0 02/05/2019 O - Administrative Law Judge Order Citation has been deleted.
4. 01004 Other 3328(A)(2) 01/18/2019 02/25/2019 $0 $825 $0 02/05/2019 O - Administrative Law Judge Order Citation has been deleted.

Investigation Summary

Investigation Nr: 113277.015
Event: 07/21/2018
Employee is struck by drilling rig tong and disemboweled

At 7:30 p.m. on July 21, 2018, Employee #1 and a coworker, employed by a drilling company, were drilling a water well. They were using a Speedstar Model SS25SD drill rig, a breakout rig tong, slips, and a breaker bar. Employee #1 was the helper for the coworker, who was operating the drill. In order to save time while breaking pipe from 40 foot sections to 20 foot sections, the drill operator and Employee #1 used a single rig tong (upper tong) and the turn table (rotary table) instead of using both upper and lower tongs to break the pipe section according to the engineered design. During this process of pipe breaking, the cable pulling the rig tong broke. The rig tong swung forward and struck Employee #1, who was standing within the rig tong's swing radius. Employee #1 was thrown onto the breaker bar. When he attempted to pull himself off the breaker bar, he was disemboweled. Emergency services transported the employee to the hospital, where he underwent multiple surgeries to repair internal organs.

Keywords: Abdomen, Broken Cable, Caught By, Construction, Drill Pipe, Drill Rig--Non-Oil, Planning, Propelled, Puncture, Rotating Parts, Struck By, Tongs, Unauthorized, Untrained, Water, Well, Work Rules

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1332875.015 29 M Hospitalized injury Drilling and boring machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.