Inspection Detail
Inspection: 1331518.015 - Letterkenny Army Depot
Inspection Information - Office: Harrisburg Area Office
Site Address:
Letterkenny Army Depot
Attn: Safety Deparment 1 Overcash Avenue Building 14
Chambersburg, PA 17201
Mailing Address:
Attn: Safety Department 1 Overcash Avenue Building 14, Chambersburg, PA 17201
Union Status: Union
SIC:
NAICS: 921190/Other General Government Support
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership:
Safety/Health: Safety
Close Conference: 01/14/2019
Emphasis:
Case Closed: 08/25/2020
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 1361185 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 5 | 1 | 6 | |||
Current Violations | 5 | 5 | ||||
Initial Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100106 E02 II B 2 | 01/15/2019 | $0 | $0 | $0 | Z - Issued | |||
2. | 01002 | Serious | 19100106 E02 IV A | 01/15/2019 | $0 | $0 | $0 | Z - Issued | |||
3. | 01003 | Serious | 19100106 E06 I | 01/15/2019 | $0 | $0 | $0 | Z - Issued | |||
4. | 01004 | Serious | 19100106 E06 II | 01/15/2019 | $0 | $0 | $0 | Z - Issued | |||
5. | 01005 | Serious | 19600059 A | 01/15/2019 | $0 | $0 | $0 | Z - Issued | |||
6. | 02001 | Other | 19600029 D | 01/15/2019 | 02/19/2019 | $0 | $0 | $0 | 02/07/2019 | F - Formal Settlement | Citation has been deleted. |
Investigation Summary
At 7:15 a.m. on July 19, 2018, three employees were replacing an empty 55 gallon drum of paint reducer with a full drum of paint reducer. As the pump equipment was being transferred from the old empty barrel to the new full barrel, an unknown ignition source started a fire with the flammable vapors from one of the drums. After the initial flash fire, an explosion occurred. Five employees were hospitalized, three employees in the area were severely burned. Two employees died.
Keywords: Burn, Drum, Explosion, Flammable Vapors, Paint Solvent
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1331518.015 | 60 | M | Fatality | ||
2 | 1331518.015 | 29 | M | Fatality | Painting and paint spraying machine operators |