Powered by GoogleTranslate

Inspection Detail

Inspection: 1331438 - Tomoegawa U S A Inc

Inspection Information - Office: Chicago North Area Office

 

Inspection Nr: 1331438
Report ID: 0524200
Date Opened: 06/27/1984

Site Address:
Tomoegawa U S A Inc
742 Glenn Ave
Wheeling, IL 60090

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:2865

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/29/1984

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 04/02/1985


Related Activity
Type Activity Nr Safety Health
Accident 360570816
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4 8
Current Violations 4 4 8
Initial Penalty $1,890 $0 $0 $0 $0 $1,890
Current Penalty $1,570 $0 $0 $0 $0 $1,570
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 07/18/1984 07/21/1984 $400 $720 $0 R - Review Commission  
2. 01002 Serious 19100023 C01 07/18/1984 07/31/1984 $270 $270 $0 -  
3. 01003 Serious 19100212 A01 07/18/1984 08/01/1984 $270 $270 $0 -  
4. 01004 Serious 19100303 G02 I 07/18/1984 07/21/1984 $630 $630 $0 -  
5. 02001 Other 19100178 K01 07/18/1984 08/08/1984 $0 $0 $0 -  
6. 02002 Other 19100212 A05 07/18/1984 08/01/1984 $0 $0 $0 -  
7. 02003 Other 19100215 A04 07/18/1984 08/27/1984 $0 $0 $0 -  
8. 02004 Other 19100215 B09 07/18/1984 08/08/1984 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14386916
Event: 06/25/1984
CAUGHT IN A RIBBON (MIXER) BLENDER

ON JUNE 25, 1984, AT APPROXIMATELY 4:30 PM, EMPLOYEE #1 WAS IN A BEARDSLEY-PIPER RIBBON BLENDER (MIXER) IN THE ACT OF CLEAING IT. HE WAS CAUGHT IN THE REVOLVING BLADES WHEN A SUPERVISOR ACTIVATED THE MIXER FROM A REMOTE CONTROL PANEL. THE SUPERVISOR ASSUMED THAT A MICRO SWITCH ON THE MIXER WAS IN THE OPEN POSITION. HE WAS NOT AWARE, NOR IN A POSITION TO OBSERVE, THAT EMPLOYEE #1 WAS IN THE MIXER. CAUSAL AND CONTRIBUTING FACTOR WAS THE LACK OF A POSITIVE LOCKOUT PROCEDURE FOR DEENERGIZING THE ELECTRICAL CIRCUIT.

Keywords: MIXER BLADE, MAINTENANCE, REMOTE CONTROL, CLEANING, MIXER, LOCKOUT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1331438 Fatality Amputation Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close