Inspection Detail
Inspection: 1330911.015 - Bloomin Brands, Inc.
Inspection Information - Office: Tampa Area Office
Site Address:
Bloomin Brands, Inc.
1951 4th St N
Saint Petersburg, FL 33704
Mailing Address:
2202 N West Shore Blvd. Suite 500, Attn. Jc Passaro'S, Tampa, FL 33607
Union Status: NonUnion
SIC:
NAICS: 722210
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/18/2018
Emphasis:
Case Closed: 11/26/2018
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1345210 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $6,652 | $0 | $0 | $0 | $0 | $6,652 |
| Current Penalty | $3,326 | $0 | $0 | $0 | $0 | $3,326 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 5A0001 | 10/29/2018 | $3,326 | $6,652 | $0 | I - Informal Settlement |
Investigation Summary
At 4:00 p.m. on June 5, 2018, Employee #1 was helping a manager move the pasta boiler so that the pipe would be positioned over the drain. One of the pasta boiler's wheels fell into the drain and tipped the pasta boiler over. The hot water splashed onto the employee's face and neck, causing second degree burns. Employee #1 was hospitalized for treatment.
Keywords: Boiler, Burn, Face, Hot Water, Neck, Struck By
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1330911.015 | 54 | M | Hospitalized injury | Cooks, except short order |
Translate