Inspection Detail
Inspection: 1330421.015 - Husky Envelope Products
Inspection Information - Office: Miosha General Industry Safety & Health Division
Site Address:
Husky Envelope Products
1225 E West Maple Rd
Walled Lake, MI 48390
Mailing Address:
1225 E West Maple Rd, Walled Lake, MI 48390
Union Status: NonUnion
SIC:
NAICS: 322232/Envelope Manufacturing
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/05/2019
Emphasis:
Case Closed: 04/09/2019
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 1359801 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $7,000 | $0 | $0 | $0 | $0 | $7,000 |
Current Penalty | $7,000 | $0 | $0 | $0 | $0 | $7,000 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100304 G05 | 03/12/2019 | $7,000 | $7,000 | $0 | Z - Issued |
Investigation Summary
At 9:00 a.m. on July 16, 2018, an employee was setting up an ink pump on a printing press in preparation for printing. As the employee kneeled down next to the pump and made contact with the upper frame of the pump, he was electrocuted. The incident investigation determined that the pump frame was energized as a result of a damaged cord and plug on the pump.
Keywords: Electric Cord, Electrocuted, Lockout/Tagout
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1330421.015 | 44 | M | Fatality | Printing machine operators |