Inspection Detail
Inspection: 1328036.015 - Huntingdon Mechanical Contractors, Inc
Inspection Information - Office: Allentown Area Office
Site Address:
Huntingdon Mechanical Contractors, Inc
2520 Wyandotte Rd
Willow Grove, PA 19090
Mailing Address:
2520 Wyandotte Rd, Willow Grove, PA 19090
Union Status: NonUnion
SIC:
NAICS: 333415/Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/06/2018
Emphasis: N:Amputate
Case Closed: 10/04/2018
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 1354153 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $5,497 | $0 | $0 | $0 | $0 | $5,497 |
Current Penalty | $4,123 | $0 | $0 | $0 | $0 | $4,123 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001A | Serious | 19100147 C04 I | 09/27/2018 | 10/17/2018 | $4,123 | $5,497 | $0 | I - Informal Settlement | ||
2. | 01001B | Serious | 19100147 C07 I | 09/27/2018 | 10/17/2018 | $0 | $0 | $0 | I - Informal Settlement |
Investigation Summary
At 10:00 a.m. on June 29, 2018, an employee was operating a press brake to bend metal. While bending the metal, the employee's fingers became caught in the press brake. Several of his fingers were amputated. He was hospitalized to treat his fingers.
Keywords: Amputated, Amputation, Caught In, Finger, Nip Point, Press Brake
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1328036.015 | 73 | M | Non Hospitalized injury | Machinists |