Investigation Summary
At 3:30 p.m. on June 6, 2018, an employee was working on a draft beer system in a walk-in cooler. The employee was trapped in the cooler due to a faulty inside door release mechanism The employee was found dead from possible carbon dioxide exposure.
Keywords: Asphyxiated, Carbon Dioxide, Confined Space, Door, Mech Malfunction
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1326390.015 | 48 | M | Fatality |