Powered by GoogleTranslate

Inspection Detail

Inspection: 13261953 - Cal Corp

Inspection Information - Office: Birmingham Area Office

 

Inspection Nr: 13261953
Report ID: 0418300
Date Opened: 04/16/1981

Site Address:
Cal Corp
1544 Mimms Ave Sw
Birmingham, AL 35211

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:1629

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice:

Ownership:  

Safety/Health: Safety

Close Conference: 04/22/1981

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 08/10/1981


Related Activity
Type Activity Nr Safety Health
Accident 350059770
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 21001A Other 19260550 A06 05/07/1981 05/27/1981 $0 $0 $0 -  
2. 21001B Other 19260550 A06 05/07/1981 05/27/1981 $0 $0 $0 -  
3. 21002A Other 19260550 B02 05/07/1981 05/27/1981 $0 $0 $0 -  
4. 21002B Other 19260550 B02 05/07/1981 05/27/1981 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14348791
Event: 04/16/1981
ELECTRIC SHOCK - DIRECT CONTACT WITH ENERGIZED PLUG

A MAINTENANCE EMPLOYEE WAS REPLACING A HYDRAULIC CYLINDER ON THE BOOM OF A PACK-A-BACK. THIS EQUIPMENT IS HEAVY MACHINERY WITH A GRAPPLE ATTACHMENT ON ITS BOOM, AND IT IS USED TO MOVE LOGS. THE HYDRAULIC CYLINDER WAS BEING HELD IN PLACE WITH A SMALL ELECTRIC HOIST MOUNTED ON AN OVERHEAD BRIDGE. THE 16-INCH ELECTRIC SUPPLY CORD FOR THE HOIST HAD A CORD CONNECTOR ON ITS END RATHER THAN AN ATTACHMENT PLUG. IT WAS CONNECTED TO A TWIST-LOCK ATTACHMENT PLUG ON THE END OF A SPRING-LOADED CORD REEL THAT WAS 10 FEET ABOVE THE FLOOR AND THAT HAD BEEN WIRED (BY AN ELECTRICIAN) TO A 480-VOLT SUPPLY CIRCUIT. (THE HOIST WAS "NEVER" UNPLUGGED.) THE EMPLOYEE WAS STRADDLING THE BOOM AND WAS LEANING ON THE BOOM TRYING TO PRY THE CYLINDER INTO PLACE. THE MOVEMENTS OF HIS BODY OVER THE CORD CAUSED THE TWIST-LOCK ATTACHMENT PLUG TO BECOME DISCONNECTED. THE ENERGIZED ATTACHMENT PLUG ON THE END OF THE CORD REEL FELL ONTO THE EMPLOYEE'S BODY AND ELECTROCUTED HIM.

Keywords: E GI V, ELECTRICAL, ELECTROCUTED, ATTACHMENT PLUG, ELECTRIC CORD

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 13261953 Fatality Electric Shock Machinery maintenance occupations
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.