Inspection Detail
Inspection: 1320946.015 - Applied Manufacturing Technologies, Inc.
Inspection Information - Office: Santa Ana District Office
Site Address:
Applied Manufacturing Technologies, Inc.
1464 N. Hundley St.
Anaheim, CA 92806
Mailing Address:
1464 N. Hundley St., Anaheim, CA 92806
Union Status: NonUnion
SIC:
NAICS: 333519
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/09/2018
Emphasis:
Case Closed: 08/13/2018
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 1335381 |
Investigation Summary
At 2:15 p.m. on May 4, 218, an employee was operating a Tampo Print Model CA-200KG machine that uses a soft silicone pad for stamping on various small parts. The employee caught her hand between the stamp pad and a part that was being stamped. No specific injury was reported; However, the employee was treated at the UCI Medical Center's Emergency Room.
Keywords: Caught Between, Hand, Hydraulic Press, Press, Stamper
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1320946.015 | 18 | F | Non Hospitalized injury | Machine operators, not specified |
Translate