Powered by GoogleTranslate

Inspection Detail

Inspection: 1320316 - Accurate Mechanical Inc

Inspection Information - Office: Appleton Area Office

 

Inspection Nr: 1320316
Report ID: 0521100
Date Opened: 08/16/1984

Site Address:
Accurate Mechanical Inc
Jefferson Court Office Bldg
Green Bay, WI 54301

Mailing Address:
722 Desnoyer Street, Kaukauna, WI 54130

Union Status: Union

SIC:1711

NAICS: 0 


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/31/1984

Emphasis:

Case Closed: 05/20/1985


Related Activity
Type Activity Nr Safety Health
Referral 900528639 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 19260352 C 09/05/1984 09/11/1984 $0 $0 $0 09/19/1984 W - Empr Withdrew  

Investigation Summary

Investigation Nr: 14512958
Event: 08/16/1984
EMPLOYEE INJURED WHEN CEMENT TANK EXPLODED

DURING THE MORNING OF AUGUST 16, 1984, EMPLOYEE #1 WAS CUTTING HOLES INTO PIPES FOR THE INSTALLATION OF THERMOMETERS. HE WAS USING AN OXYGEN AND ACETYLENE SYSTEM WITH A CUTTING TORCH. ONE OF THE PIPES HE WAS CUTTING LED DOWN INTO A CEMENT TANK, WHICH WAS 16 FEET BY 8 FEET BY 6 FEET DEEP. ABOUT 21 DAYS PRIOR TO THE ACCIDENT, ANOTHER CONTRACTOR HAD APPLIED A COAL TAR EPOXY SEALER TO THE FLOOR AND WALLS OF THE TANK. THE SEALER WAS FLAMMABLE IN A LIQUID STATE. IT HAD A CURING TIME OF 14 TO 20 DAYS AT 30 TO 50 DEGREES F (LESS TIME AT A HIGHER TEMPERATURE). THE TANK WAS NOT VENTILATED AFTER THE SEALER WAS APPLIED. THE TANK WAS LOCATED BELOW A BUILDING, AND HAD ONLY A FEW SMALL OPENINGS AT THE TOP. IT CAN BE SPECULATED THAT WHEN EMPLOYEE #1 WAS CUTTING A HOLE, HOT SPARKS FELL INTO THE TANK, IGNITING THE VAPORS.

Keywords: FLAMMABLE VAPORS, WORK RULES, WELDER, CONSTRUCTION, TORCH, EXPLOSION, SPARK, TANK, CUTTING AND BURNING

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1320316 Hospitalized injury Burn/Scald(Heat) Plumbers, pipefitters and steamfitters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.