Inspection Detail
Inspection: 1319392.015 - Diversified Asphalt Products, Inc.
Inspection Information - Office: Santa Ana District Office
Site Address:
Diversified Asphalt Products, Inc.
1227 N. Olive St.
Anaheim, CA 92801
Mailing Address:
1227 N. Olive St., Anaheim, CA 92801
Union Status: NonUnion
SIC:
NAICS: 324121/Asphalt Paving Mixture and Block Manufacturing
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/12/2018
Emphasis:
Case Closed: 11/16/2018
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 1342034 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 2 | ||||
Current Violations | 2 | 2 | ||||
Initial Penalty | $0 | $0 | $0 | $5,275 | $0 | $5,275 |
Current Penalty | $0 | $0 | $0 | $2,275 | $0 | $2,275 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 342(A) | 09/12/2018 | $2,000 | $5,000 | $0 | 09/18/2018 | C - Contested | ||
2. | 01002 | Other | 1510(C) | 09/12/2018 | 10/17/2018 | $275 | $275 | $0 | Z - Issued |
Investigation Summary
At 4:30 p.m. on May 22, 2018, an employee was filling a truck with high performance asphalt sealant. The employee manually stuck a valve open on the truck to save time, but forgot to close it before activating the reverse flow. This resulted in hot sealant splashing onto the employee, resulting in third degree burns on both arms. The employee was wearing gloves, goggles, and a short sleeve shirt at the time of the accident.
Keywords: Arm, Asphalt, Burn, Valve
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1319392.015 | 66 | M | Hospitalized injury | Truck drivers, light |