Inspection Detail
Inspection: 1318037.015 - Industrial Solutions, Inc
Inspection Information - Office: Houston South Area Office
Site Address:
Industrial Solutions, Inc
11500 Bay Area Blvd
Pasadena, TX 77507
Mailing Address:
6022 Sycamore Ave, Pasadena, TX 77503
Union Status: NonUnion
SIC:
NAICS: 238990/All Other Specialty Trade Contractors
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/19/2018
Emphasis: N:Chemnep
Case Closed: 07/10/2018
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 1340695 | Yes | |
Inspection | 1318150 | Yes | |
Inspection | 1317992 | Yes | |
Inspection | 1318024 | Yes | |
Inspection | 1317675 | Yes | |
Inspection | 1325915 | Yes | |
Inspection | 1318160 | Yes | |
Inspection | 1318127 | Yes |
Investigation Summary
At 10:15 a.m. on May 19, 2018, Employees #1 through #6, employed by an industrial services company, were engaged in insulation and painting work at an industrial plant. A reactor relief valve opened, releasing materials that ignited in a flash fire. All six employees were burned. Emergency services transported the employees to the hospital, where they were admitted and treated for burns.
Keywords: Burn, Construction, Fire, Flammable Liquid, Flammable Vapors, Maintenance, Paint, Pressure Release, Reactor, Repair, Valve
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1318037.015 | 35 | M | Hospitalized injury | ||
2 | 1318037.015 | 55 | M | Hospitalized injury | ||
3 | 1318037.015 | 52 | M | Hospitalized injury | ||
4 | 1318037.015 | 42 | M | Hospitalized injury | ||
5 | 1318037.015 | 42 | M | Hospitalized injury | Occupation not reported | |
6 | 1318037.015 | 47 | M | Hospitalized injury |