Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1318024.015 - James H. Jackson Industries

Inspection Information - Office: Houston South Area Office

 

Inspection Nr: 1318024.015
Report ID: 0626700
Date Opened: 05/19/2018

Site Address:
James H. Jackson Industries
11500 Bay Area Blvd.
Pasadena, TX 77507

Mailing Address:
P O Box 1079, La Porte, TX 77572

Union Status: NonUnion

SIC:

NAICS: 333992/Welding and Soldering Equipment Manufacturing


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/19/2018

Emphasis: N:Chemnep

Case Closed: 07/31/2018


Related Activity
Type Activity Nr Safety Health
Referral 1340695 Yes
Inspection 1318150 Yes
Inspection 1317992 Yes
Inspection 1317675 Yes
Inspection 1325915 Yes
Inspection 1318037 Yes
Inspection 1318160 Yes
Inspection 1318127 Yes
Case Status: CLOSED

Investigation Summary

Investigation Nr: 105854.015
Event: 05/19/2018
Five employees are injured in a flash fire

At 10:15 a.m. on May 19, 2018, an employee was performing insulation work. The relief valve on the reactor lifted and a fire occurred. The were 5 employees injuried and they sustained burns, contusions, and lacerations.

Keywords: Burn, Contusion, Fire Brigade, Laceration, Reactor, Valve

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1318024.015 42 M Hospitalized injury
2 1318024.015 28 M Hospitalized injury
3 1318024.015 39 M Hospitalized injury
4 1318024.015 37 M Hospitalized injury
5 1318024.015 51 M Hospitalized injury
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.