Inspection: 1315471.015 - J.D. Roofing And Exteriors Inc.
Inspection Information - Office: Cleveland Area Office
Site Address:
J.D. Roofing And Exteriors Inc.
7285 Meadow Lane
Parma, OH 44129
Mailing Address:
10819 Beech St Ne, Alliance, OH 44601
Union Status: NonUnion
SIC:
NAICS: 238160/Roofing Contractors
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/11/2018
Emphasis: L:Fall
Case Closed: 08/19/2020
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1336170 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 2 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $8,536 | $0 | $0 | $0 | $0 | $8,536 |
| Current Penalty | $4,268 | $0 | $0 | $0 | $0 | $4,268 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 19260021 B02 | 06/13/2018 | 08/07/2018 | $4,268 | $4,268 | $0 | I - Informal Settlement | ||
| 2. | 01001B | Serious | 19260416 A01 | 06/13/2018 | $0 | $4,268 | $0 | I - Informal Settlement |
Investigation Summary
On May 11, 2018, Employees #1 and #2, employed by a roofing company, were installing roofing materials on an existing two-story residential structure. They were setting up a TranzSporter Platform Hoist, Model TPZ250, which was attached to a 28-foot aluminum ladder. Multiple energized power lines transmitting 7,260 volts ran above them. As Employee #1 stood and secured the ladder at its base, Employee #1 began to drive the ladder skyward. The ladder came into contact with an energized power line and became energized. Both employees sustained electrical shocks. They were transported to the hospital, where they were admitted and treated.
Keywords: Burn, Contact, Electric Shock, Energized, Hoist, Installing, Ladder, Power Lines, Residential Construction, Roof, Roofer
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1315471.015 | 26 | M | Hospitalized injury | Roofers | |
| 2 | 1315471.015 | 25 | M | Hospitalized injury | Roofers |