Case Status: CLOSED

Inspection: 1315427.015 - Kraton Chemical, Llc.

Inspection Information - Office: Jacksonville Area Office

 

Inspection Nr: 1315427.015
Report ID: 0419700
Date Opened: 05/09/2018

Site Address:
Kraton Chemical, Llc.
2 South Everitt Ave
Panama City, FL 32405

Mailing Address:
2 South Everitt Ave, Panama City, FL 32405

Union Status: NonUnion

SIC:

NAICS: 325194 


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/10/2018

Emphasis:

Case Closed: 12/26/2018


Related Activity
Type Activity Nr Safety Health
Referral 1335114 Yes
Case Status: CLOSED

Investigation Summary

Investigation Nr: 105498.015
Event: 05/05/2018
Employee is sprayed with heated chemical liquids and is hosp

At 12:30 a.m. on May 5, 2018, an employee was troubleshooting some equipment and had removed a flange to change a filter when the pressure in the line sprayed the employee with heated chemical liquids. The employee was hospitalized with burns to his face and arm.

Keywords: Arm, Chemical Burn, Face, Maintenance

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1315427.015 25 M Hospitalized injury Laborers, except construction
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.