Inspection Detail
Inspection: 1312438.015 - All Temperature Systems Inc.
Inspection Information - Office: Appleton Area Office
Site Address:
All Temperature Systems Inc.
113 N. Western A
Waupaca, WI 54981
Mailing Address:
N2505 State Road 22, Waupaca, WI 54981
Union Status: NonUnion
SIC:
NAICS: 238220/ Plumbing, Heating, and Air-Conditioning Contractors
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/30/2018
Emphasis: L:Fall
Case Closed: 09/11/2018
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 1330616 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 1 | 3 | |||
Current Violations | 2 | 1 | 3 | |||
Initial Penalty | $6,652 | $0 | $0 | $5,000 | $0 | $11,652 |
Current Penalty | $6,652 | $0 | $0 | $1,000 | $0 | $7,652 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001A | Serious | 19100023 C11 | 08/01/2018 | 08/29/2018 | $3,880 | $3,880 | $0 | I - Informal Settlement | ||
2. | 01001B | Serious | 19100030 B01 | 08/01/2018 | $0 | $0 | $0 | I - Informal Settlement | |||
3. | 01002A | Serious | 19100028 B13 III B | 08/01/2018 | 08/29/2018 | $2,772 | $2,772 | $0 | I - Informal Settlement | ||
4. | 01002B | Serious | 19100030 A03 | 08/01/2018 | 09/20/2018 | $0 | $0 | $0 | I - Informal Settlement | ||
5. | 02001 | Other | 19040039 A02 | 08/01/2018 | $1,000 | $5,000 | $0 | I - Informal Settlement |
Investigation Summary
At 9:33 a.m. on April 20, 2018, Employee #1 and a coworker, employed by a heating and cooling services company, were engaged in repair work on the roof of a commercial building. They had used a 17-foot Vulcan Multi-Task Ladder ES-17-A-SM in the extension mode to access the roof. They were replacing a broken gas line on a Bryant heating and air conditioning unit, Model 580FJV6060115AB, Serial Number 0903G50230, which was located on the building's low-sloped roof approximately 29 feet away from the roof's edge. The roof was approximately 12.08 feet above the asphalt parking lot. Employee #1 went to access the ladder. He first had to kick snow from the roof's edge and away from the ladder. As Employee #1 attempted to climb onto the ladder, he fell. Emergency services were called, and Employee #1 was transported to the hospital. He was admitted and treated for traumatic brain injury, a fractured skull, and other injuries, including fractures to six ribs, a fractured left shoulder bone, micro fractures to multiple vertebrae, a collapsed lung, and left arm muscle injuries.
Keywords: Arm, Brain, Fall, Fracture, Ladder, Lung, Rib, Roof, Shoulder, Vertebra
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1312438.015 | 44 | M | Hospitalized injury | Heating, air conditioning, and refrig. mechanics |